3/22/2021 0 Comments Download Beckett Cb151Ul Manual
For those installations not requiring a chimney, such as through-the-wall vented appliances, follow the instructions given by the appliance and power venter (if used) manufacturers.Direct air supply and sidewall venting Some AFG burners are equipped with combustion air boots to allow use of outside air for combustion.When sidewall venting appliances, carefully follow appliance and power venter instructions for installation and wiring.
If the burner is not supplied with a reliable combustion air source, the burner cannot properly burn the fuel. This would result in incomplete com- bustion, causing sooting and possible emission of carbon monoxide. Severe personal injury, death or substantial property damage could occur. Appliance located in confined space The confined space should have two (2) permanent openings: one near the top of the enclosure and one near the bottom of the enclosure. Beckett Cb151Ul Free Area OfEach opening shall have a free area of not less than (1) one square inch per 1,000 BTU s per hour of the total input rating of all appliances within the enclosure. The openings shall have free access to the building interior, which should have adequate infiltration from the outside. Exhaust fans and other air -using devices Size air openings large enough to allow for all air-using devices in addition to the minimum area required for combustion air. If there is any possibility of the equipment room developing negative pressure (because of exhaust fans or clothes dryers, for example), either pipe combustion air directly to the burner or provide a sealed enclosure for the burner and supply it with its own combustion air supply. Outside air kit applications Refer to separate instruction sheet supplied with AFG outside air kit for installation. This optional kit allows combustion air to be piped directly to the burner. Part number 51747.) Y ou must install the outside air kit strictly following the kit instal- lation instructions. Do not attempt to install outside air piping without using the AFG outside air kit and instructions. Failure to do so could result in burner or heating appliance failure, causing potential severe personal injury, death or sub- stantial property damage. Prepare burner site T able 2 Minimum combustion chamber dimensions Clearances to burner and appliance Provide space around burner and appliance for easy service and mainte- nance. Check minimum clearances against those shown by the appliance manufac- turer and by applicable building codes. Combustion chamber Burner retrofitting Verify that the appliance combustion chamber provides at least the minimum dimensions given in T able 2. When retrofitting an appliance that has a stainless steel chamber A chamber burnout could result from the use of a high perf ormance burner. Failure to comply could result in damage to heating equipment.
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |